snapshot of https://github.com/seaweedfs/seaweedfs.git (master, 2026-09-16; blobs > 131072B omitted)
Some checks failed
go: build dev binaries / cleanup (push) Successful in 4s
Codespell / Check for spelling errors (push) Failing after 3s
docker: build dev containers / build-rust-binaries (amd64, x86_64-unknown-linux-musl) (push) Failing after 3s
docker: build dev containers / build-dev-containers (push) Has been skipped
docker: build dev containers / build-rust-binaries (arm64, true, aarch64-unknown-linux-musl) (push) Failing after 3s
End to End / FUSE Mount (push) Failing after 2s
EC Integration Tests / EC Integration Tests (push) Failing after 30s
FUSE DLM Integration Tests / FUSE DLM Integration Tests (push) Failing after 3s
FUSE Volume Server Failover Tests / FUSE Volume Server Failover (push) Failing after 3s
FUSE Integration Tests / FUSE Integration Testing (push) Failing after 2s
FUSE P2P Peer Chunk Sharing Integration Tests / FUSE P2P Peer Chunk Sharing (push) Failing after 3s
go: build binary / Go Vet (push) Failing after 2s
go: build binary / Go Vet 32-bit (push) Failing after 3s
go: build binary / Build (push) Failing after 4s
go: build binary / Build cross-platform (freebsd/amd64) (push) Failing after 3s
go: build binary / Build cross-platform (windows/amd64) (push) Failing after 3s
go: build binary / Build cross-platform (darwin/arm64) (push) Failing after 3s
go: build binary / Build cross-platform (windows/arm64) (push) Failing after 3s
go: build binary / Test (push) Failing after 2s
go: build binary / Test 32-bit (push) Failing after 3s
helm: lint and test charts / lint-test (push) Failing after 3s
Java Client Integration Tests / Java Integration Tests (11) (push) Failing after 3s
Java Client Integration Tests / Java Integration Tests (17) (push) Failing after 3s
go: build dev binaries / build_dev_linux_windows (amd64, linux) (push) Failing after 2s
go: build dev binaries / build_dev_linux_windows (amd64, windows) (push) Failing after 3s
go: build dev binaries / build_dev_darwin (amd64, darwin) (push) Has been skipped
go: build dev binaries / build_dev_darwin (arm64, darwin) (push) Has been skipped
Java Client Unit Tests / Java Unit Tests (11) (push) Failing after 3s
Java Client Unit Tests / Java Unit Tests (17) (push) Failing after 2s
Java Client Unit Tests / Java Unit Tests (21) (push) Failing after 3s
Java Client Unit Tests / Java Unit Tests (8) (push) Failing after 3s
Kafka Quick Test (Load Test with Schema Registry) / Kafka Client Load Test (Quick) (push) Failing after 3s
Kafka Gateway Tests / Kafka Unit Tests (unit-tests-1) (push) Failing after 11s
Kafka Gateway Tests / Kafka Integration Tests (Critical) (integration-1) (push) Failing after 3s
Kafka Gateway Tests / Kafka End-to-End Tests (with SMQ) (e2e-1) (push) Failing after 3s
Kafka Gateway Tests / Kafka Consumer Group Tests (Highly Isolated) (consumer-group-1) (push) Failing after 2s
Kafka Gateway Tests / Kafka Client Compatibility (with SMQ) (client-compat-1) (push) Failing after 3s
Kafka Gateway Tests / Kafka SMQ Integration Tests (Full Stack) (smq-integration-1) (push) Failing after 3s
Kafka Gateway Tests / Kafka Protocol Tests (Isolated) (protocol-1) (push) Failing after 3s
KMS Tests / KMS Provider Integration Tests (push) Failing after 2s
KMS Tests / S3 KMS End-to-End Tests (push) Failing after 3s
Master Cold Start Tests / Master Cold Start Tests (push) Failing after 4s
Metadata Subscribe Integration Tests / Metadata Subscribe Integration Tests (push) Failing after 3s
Multi-Master Tests / Multi-Master Failover Tests (push) Failing after 3s
Performance / CPU and Heap Profile (push) Failing after 2s
Performance / S3 Read/Write Benchmark (rust volume) (push) Failing after 3s
pjdfstest POSIX Compliance / pjdfstest (push) Failing after 2s
Plugin Worker Integration Tests / Plugin Worker: erasure_coding (push) Failing after 3s
Plugin Worker Integration Tests / Plugin Worker: vacuum (push) Failing after 3s
Rust Volume Server Tests / Rust Integration Tests (push) Failing after 3s
Rust Volume Server Tests / Go Tests with Rust Volume (grpc - Shard 1) (push) Failing after 2s
Rust Volume Server Tests / Go Tests with Rust Volume (http - Shard 1) (push) Failing after 3s
Rust Volume Server Tests / Go Tests with Rust Volume (grpc - Shard 2) (push) Failing after 3s
Rust Volume Server Tests / Go Tests with Rust Volume (http - Shard 2) (push) Failing after 3s
Rust Volume Server Tests / Go Tests with Rust Volume (grpc - Shard 3) (push) Failing after 3s
S3 IAM Integration Tests / S3 IAM Distributed Tests (push) Failing after 2s
S3 IAM Integration Tests / S3 IAM Performance Tests (push) Failing after 3s
Performance / Throughput Benchmark (go volume) (push) Failing after 3s
Performance / Throughput Benchmark (rust volume) (push) Failing after 2s
Performance / S3 Read/Write Benchmark (go volume) (push) Failing after 3s
Plugin Worker Integration Tests / Plugin Worker: volume_balance (push) Failing after 3s
PostgreSQL Gateway Tests / PostgreSQL Basic Tests (push) Failing after 3s
Rust Volume Server Tests / Rust Unit Tests (push) Failing after 2s
Rust Volume Server Tests / Go Tests with Rust Volume (http - Shard 3) (push) Failing after 3s
Rust Plugin Worker Tests / Rust Plugin Worker Build and Unit Tests (push) Failing after 3s
rust: build dev volume server binaries / cleanup (push) Successful in 3s
S3 ETag and ACL Tests / S3 ETag + ACL Integration Tests (push) Failing after 3s
S3 IAM Integration Tests / IAM Unit Tests (push) Failing after 3s
S3 IAM Integration Tests / S3 IAM Integration Tests (advanced) (push) Failing after 3s
S3 IAM Integration Tests / S3 IAM Integration Tests (basic) (push) Failing after 2s
S3 IAM Integration Tests / S3 IAM Integration Tests (group) (push) Failing after 3s
S3 IAM Integration Tests / S3 IAM Integration Tests (policy-enforcement) (push) Failing after 2s
S3 IAM Integration Tests / S3 IAM Integration Tests (sts) (push) Failing after 4s
S3 Keycloak Integration Tests / S3 Keycloak Integration Tests (push) Failing after 3s
S3 PyArrow Parquet Tests / PyArrow Parquet Tests (Python 3.11) (push) Failing after 3s
S3 PyArrow Parquet Tests / Go Unit Tests (Implicit Directory) (push) Has been cancelled
S3 PyArrow Parquet Tests / PyArrow Parquet Tests (Python 3.12) (push) Has been cancelled
rust: build dev volume server binaries / build-rust-volume-dev-darwin (darwin-amd64, x86_64-apple-darwin) (push) Has been cancelled
rust: build dev volume server binaries / build-rust-volume-dev-darwin (darwin-arm64, aarch64-apple-darwin) (push) Has been cancelled
rust: build dev volume server binaries / build-rust-volume-dev-linux (linux-amd64, x86_64-unknown-linux-gnu) (push) Has been cancelled
S3 PyArrow Parquet Tests / PyArrow Parquet Tests (Python 3.9) (push) Has been cancelled
S3 Proxy Signature Tests / S3 Proxy Signature Verification Tests (push) Has been cancelled
S3 SDK V2 Route Disambiguation Tests / S3 SDK V2 Routing Tests (push) Has been cancelled
S3 SSE Tests / S3 SSE Integration Tests (quick) (push) Has been cancelled
S3 SSE Tests / S3 SSE Compatibility Test (push) Has been cancelled
S3 SSE Tests / S3 SSE Metadata Persistence Test (push) Has been cancelled
S3 SSE Tests / S3 SSE Copy Operations Test (push) Has been cancelled
S3 SSE Tests / S3 SSE Multipart Upload Test (push) Has been cancelled
S3 SSE Tests / S3 SSE Performance Test (push) Has been cancelled
S3 SSE Tests / S3 Volume Encryption Test (push) Has been cancelled
S3 SSE Tests / S3 SSE Integration Tests (comprehensive) (push) Has been cancelled
Spark Integration Tests / Spark Integration Tests (push) Failing after 2s
Telemetry Integration Tests / telemetry-integration-test (push) Failing after 3s
Volume Server Integration Tests / Volume Server Integration Tests (grpc - Shard 1) (push) Failing after 3s
Volume Server Integration Tests / Volume Server Integration Tests (http - Shard 1) (push) Failing after 3s
Ceph S3 tests / Basic S3 tests (KV store) (push) Has been cancelled
Ceph S3 tests / S3 Versioning & Object Lock tests (push) Has been cancelled
S3 Policy Integration Tests / S3 Policy Unit Tests (push) Failing after 3s
Ceph S3 tests / S3 CORS tests (push) Has been cancelled
Ceph S3 tests / SeaweedFS Custom S3 Copy tests (push) Has been cancelled
Ceph S3 tests / Basic S3 tests (SQL store) (push) Has been cancelled
test s3 over https using aws-cli / awscli-tests (push) Has been cancelled
TLS Rotation Integration Tests / TLS Rotation Integration Tests (push) Has been cancelled
Vacuum Integration Tests / Vacuum Integration Tests (push) Has been cancelled
S3 Policy Integration Tests / S3 Policy Variables Integration Tests (push) Failing after 3s
S3 Policy Integration Tests / S3 Policy Enforcement Integration Tests (advanced-policy) (push) Failing after 3s
S3 Policy Integration Tests / S3 Policy Enforcement Integration Tests (basic-policy) (push) Failing after 2s
S3 Policy Integration Tests / S3 Policy Enforcement Integration Tests (contextual-policy) (push) Failing after 4s
S3 Policy Integration Tests / Trusted Proxy Detection Tests (push) Failing after 2s
S3 Policy Integration Tests / S3 Policy Shell Integration Tests (push) Failing after 3s
Samba on FUSE Integration / samba-integration (push) Failing after 2s
SFTP Integration Tests / SFTP Integration Testing (push) Failing after 3s
terraform: validate and test modules / fmt, validate, plan-level tests (push) Failing after 3s
terraform: validate and test modules / local cluster smoke test (real weed) (push) Failing after 2s
Volume Server Integration Tests / Volume Server Integration Tests (grpc - Shard 3) (push) Failing after 3s
Volume Server Integration Tests / Volume Server Integration Tests (grpc - Shard 2) (push) Failing after 3s
Volume Server Integration Tests / Volume Server Integration Tests (http - Shard 2) (push) Failing after 2s
Volume Server Integration Tests / Volume Server Integration Tests (http - Shard 3) (push) Failing after 5s
mount: windows conformance / WinFsp conformance (push) Has been cancelled
mount: windows / Mount on Windows (push) Has been cancelled

This commit is contained in:
upstream-mirror
2026-09-16 03:23:42 +05:00
commit 89f5be005d
3997 changed files with 961970 additions and 0 deletions

View File

@@ -0,0 +1,338 @@
package wdclient
import (
"context"
"errors"
"fmt"
"math/rand"
"sort"
"strconv"
"strings"
"golang.org/x/sync/singleflight"
"github.com/seaweedfs/seaweedfs/weed/glog"
"github.com/seaweedfs/seaweedfs/weed/pb"
"github.com/seaweedfs/seaweedfs/weed/util"
)
// VolumeLocationProvider is the interface for looking up volume locations
// This allows different implementations (master subscription, filer queries, etc.)
type VolumeLocationProvider interface {
// LookupVolumeIds looks up volume locations for the given volume IDs
// Returns a map of volume ID to locations
LookupVolumeIds(ctx context.Context, volumeIds []string) (map[string][]Location, error)
}
// vidMapClient provides volume location caching with pluggable lookup
// It wraps the battle-tested vidMap with customizable volume lookup strategies
type vidMapClient struct {
vidMap *vidMap
provider VolumeLocationProvider
vidLookupGroup singleflight.Group
}
const (
// DefaultVidMapCacheSize is the default number of resets a volume location
// survives without being relearned. This provides cache history when
// volumes move between servers.
DefaultVidMapCacheSize = 5
)
// newVidMapClient creates a new client with the given provider and data center
func newVidMapClient(provider VolumeLocationProvider, dataCenter string, cacheSize int) *vidMapClient {
return &vidMapClient{
vidMap: newVidMap(dataCenter, cacheSize),
provider: provider,
}
}
// GetLookupFileIdFunction returns a function that can be used to lookup file IDs
func (vc *vidMapClient) GetLookupFileIdFunction() LookupFileIdFunctionType {
return vc.LookupFileIdWithFallback
}
// LookupFileIdWithFallback resolves a "<vid>,<cookie>" file id to a list of
// HTTP read URLs, using the cached vidMap when populated and falling back to
// the provider for a fresh lookup on miss. URLs are returned in preference
// order: same-DC local, same-DC remote-tier, then the other data centers on
// the same footing -- mirroring the cached vidMap path so both routes agree.
// Concurrent misses for the same vid are coalesced via the singleflight group
// on LookupVolumeIdsWithFallback.
func (vc *vidMapClient) LookupFileIdWithFallback(ctx context.Context, fileId string) (fullUrls []string, err error) {
// Try cache first
dataCenter := vc.vidMap.DataCenter
fullUrls, err = vc.vidMap.LookupFileId(ctx, fileId)
// Cache hit - return immediately
if err == nil && len(fullUrls) > 0 {
return
}
// Cache miss - extract volume ID from file ID (format: "volumeId,needle_id_cookie")
if fileId == "" {
return nil, fmt.Errorf("empty fileId")
}
parts := strings.Split(fileId, ",")
if len(parts) != 2 {
return nil, fmt.Errorf("invalid fileId %s", fileId)
}
volumeId := parts[0]
// Use shared lookup logic with batching and singleflight
vidLocations, err := vc.LookupVolumeIdsWithFallback(ctx, []string{volumeId})
// Check for partial results first (important for multi-volume batched lookups)
locations, found := vidLocations[volumeId]
if !found || len(locations) == 0 {
// Volume not found - return specific error with context from lookup if available
if err != nil {
return nil, fmt.Errorf("volume %s not found for fileId %s: %w", volumeId, fileId, err)
}
return nil, fmt.Errorf("volume %s not found for fileId %s", volumeId, fileId)
}
// Volume found successfully - ignore any errors about other volumes
// (not relevant for single-volume lookup, but defensive for future batching)
// Build HTTP URLs from locations, preferring same data center
var sameDcUrls, otherDcUrls []string
localUrls := make(map[string]bool)
for _, loc := range locations {
httpUrl := "http://" + loc.Url + "/" + fileId
glog.V(4).Infof("lookup %s => %s, data in remote storage tier: %v", fileId, loc.Url, loc.DataInRemote)
if !loc.DataInRemote {
localUrls[httpUrl] = true
}
if dataCenter != "" && dataCenter == loc.DataCenter {
sameDcUrls = append(sameDcUrls, httpUrl)
} else {
otherDcUrls = append(otherDcUrls, httpUrl)
}
}
// Shuffle to distribute load across volume servers
rand.Shuffle(len(sameDcUrls), func(i, j int) { sameDcUrls[i], sameDcUrls[j] = sameDcUrls[j], sameDcUrls[i] })
rand.Shuffle(len(otherDcUrls), func(i, j int) { otherDcUrls[i], otherDcUrls[j] = otherDcUrls[j], otherDcUrls[i] })
// Local replicas go first inside each data center, but never ahead of the
// data-center preference itself. Mirrors vidMap.LookupVolumeServerUrl so
// all client lookup paths agree.
if len(localUrls) > 0 {
sameDcUrls = util.ReorderToFront(localUrls, sameDcUrls)
otherDcUrls = util.ReorderToFront(localUrls, otherDcUrls)
}
fullUrls = append(sameDcUrls, otherDcUrls...)
return fullUrls, nil
}
// LookupVolumeIdsWithFallback looks up volume locations, querying provider if not in cache.
// Uses singleflight to coalesce concurrent requests for the same batch of volumes.
//
// IMPORTANT: This function may return PARTIAL results with a non-nil error.
// The result map contains successfully looked up volumes, while the error aggregates
// failures for volumes that couldn't be found or had lookup errors.
//
// Callers MUST check both the result map AND the error:
// - result != nil && err == nil: All volumes found successfully
// - result != nil && err != nil: Some volumes found, some failed (check both)
// - result == nil && err != nil: Complete failure (connection error, etc.)
//
// Example usage:
//
// locs, err := mc.LookupVolumeIdsWithFallback(ctx, []string{"1", "2", "999"})
// if len(locs) > 0 {
// // Process successfully found volumes
// }
// if err != nil {
// // Log/handle failed volumes
// }
func (vc *vidMapClient) LookupVolumeIdsWithFallback(ctx context.Context, volumeIds []string) (map[string][]Location, error) {
result := make(map[string][]Location)
var needsLookup []string
var lookupErrors []error
// Check cache first and parse volume IDs once
vidStringToUint := make(map[string]uint32, len(volumeIds))
for _, vidString := range volumeIds {
vid, err := strconv.ParseUint(vidString, 10, 32)
if err != nil {
return nil, fmt.Errorf("invalid volume id %s: %v", vidString, err)
}
vidStringToUint[vidString] = uint32(vid)
locations, found := vc.vidMap.GetLocations(uint32(vid))
if found && len(locations) > 0 {
result[vidString] = locations
} else {
needsLookup = append(needsLookup, vidString)
}
}
if len(needsLookup) == 0 {
return result, nil
}
// Batch query all missing volumes using singleflight on the batch key
// Sort for stable key to coalesce identical batches
sort.Strings(needsLookup)
batchKey := strings.Join(needsLookup, ",")
sfResult, err, _ := vc.vidLookupGroup.Do(batchKey, func() (interface{}, error) {
// Double-check cache for volumes that might have been populated while waiting
stillNeedLookup := make([]string, 0, len(needsLookup))
batchResult := make(map[string][]Location)
for _, vidString := range needsLookup {
vid := vidStringToUint[vidString] // Use pre-parsed value
if locations, found := vc.vidMap.GetLocations(vid); found && len(locations) > 0 {
batchResult[vidString] = locations
} else {
stillNeedLookup = append(stillNeedLookup, vidString)
}
}
if len(stillNeedLookup) == 0 {
return batchResult, nil
}
// Query provider with batched volume IDs
glog.V(2).Infof("Looking up %d volumes from provider: %v", len(stillNeedLookup), stillNeedLookup)
providerResults, err := vc.provider.LookupVolumeIds(ctx, stillNeedLookup)
if err != nil {
return batchResult, fmt.Errorf("provider lookup failed: %w", err)
}
// Update cache with results
for vidString, locations := range providerResults {
vid, err := strconv.ParseUint(vidString, 10, 32)
if err != nil {
glog.Warningf("Failed to parse volume id '%s': %v", vidString, err)
continue
}
for _, loc := range locations {
vc.addLocation(uint32(vid), loc)
}
if len(locations) > 0 {
batchResult[vidString] = locations
}
}
return batchResult, nil
})
if err != nil {
lookupErrors = append(lookupErrors, err)
}
// Merge singleflight batch results
if batchLocations, ok := sfResult.(map[string][]Location); ok {
for vid, locs := range batchLocations {
result[vid] = locs
}
}
// Check for volumes that still weren't found
for _, vidString := range needsLookup {
if _, found := result[vidString]; !found {
lookupErrors = append(lookupErrors, fmt.Errorf("volume %s not found", vidString))
}
}
// Return aggregated errors
return result, errors.Join(lookupErrors...)
}
// LookupVolumeIdsAuthoritative bypasses the asynchronously maintained vid map.
// Use it when a stale positive result is unsafe, such as before serving cache
// payload from a Volume that the master may have retired. The provider still
// batches all requested IDs into one lookup, returns a nil map when it got no
// answer, and reports the volumes the master does not serve as errors.
func (vc *vidMapClient) LookupVolumeIdsAuthoritative(ctx context.Context, volumeIds []string) (map[string][]Location, error) {
return vc.provider.LookupVolumeIds(ctx, volumeIds)
}
// Public methods for external access
//
// The vidMap itself is never replaced, so these all read the one map under its
// own lock. Resets bump its generation instead of swapping in a fresh instance.
// GetLocations safely retrieves volume locations
func (vc *vidMapClient) GetLocations(vid uint32) (locations []Location, found bool) {
return vc.vidMap.GetLocations(vid)
}
// GetLocationsClone safely retrieves a clone of volume locations
func (vc *vidMapClient) GetLocationsClone(vid uint32) (locations []Location, found bool) {
return vc.vidMap.GetLocationsClone(vid)
}
// GetVidLocations safely retrieves volume locations by string ID
func (vc *vidMapClient) GetVidLocations(vid string) (locations []Location, err error) {
return vc.vidMap.GetVidLocations(vid)
}
// LookupFileId safely looks up URLs for a file ID
func (vc *vidMapClient) LookupFileId(ctx context.Context, fileId string) (fullUrls []string, err error) {
return vc.vidMap.LookupFileId(ctx, fileId)
}
// LookupVolumeServerUrl safely looks up volume server URLs
func (vc *vidMapClient) LookupVolumeServerUrl(vid string) (serverUrls []string, err error) {
return vc.vidMap.LookupVolumeServerUrl(vid)
}
// HasVolumeServer reports whether addr is currently a known volume server
// (hosts at least one volume or EC shard) in the cached vid map. Used by
// admission paths that must only contact peers learned from the master.
func (vc *vidMapClient) HasVolumeServer(addr pb.ServerAddress) bool {
return vc.vidMap.hasVolumeServer(addr)
}
// GetDataCenter safely retrieves the data center
func (vc *vidMapClient) GetDataCenter() string {
return vc.vidMap.DataCenter
}
// Thread-safe helpers for vidMap operations
// addLocation adds a volume location
func (vc *vidMapClient) addLocation(vid uint32, location Location) {
vc.vidMap.addLocation(vid, location)
}
// deleteLocation removes a volume location
func (vc *vidMapClient) deleteLocation(vid uint32, location Location) {
vc.vidMap.deleteLocation(vid, location)
}
// addEcLocation adds an EC volume location
func (vc *vidMapClient) addEcLocation(vid uint32, location Location) {
vc.vidMap.addEcLocation(vid, location)
}
// deleteEcLocation removes an EC volume location
func (vc *vidMapClient) deleteEcLocation(vid uint32, location Location) {
vc.vidMap.deleteEcLocation(vid, location)
}
// resetVidMap starts a new generation, as when the master changes: what the
// previous one told us stays readable until it is relearned or expires.
func (vc *vidMapClient) resetVidMap() {
vc.vidMap.reset()
}
// InvalidateCache removes all cached locations for a volume ID
func (vc *vidMapClient) InvalidateCache(fileId string) {
parts := strings.Split(fileId, ",")
vidString := parts[0]
vid, err := strconv.ParseUint(vidString, 10, 32)
if err != nil {
return
}
vc.vidMap.deleteVid(uint32(vid))
}